What Is EPS (Expanded Polystyrene) and Why Does It Change a Property’s Insurance Risk?

Posted on August 17, 2026   |
by   dev@highjumpdigital.com dev@highjumpdigital.com

"What percentage of the building contains EPS?" is one of the more unsettling questions on a property proposal form, mostly because plenty of owners have no idea how to answer it. The answer matters, though, because it can move your premium and your excess, and in some cases it decides whether an insurer will quote at all. Expanded polystyrene insurance has become a recognised sticking point in the Australian market, with capacity tightening and underwriting scrutiny increasing, and food, cold storage and warehousing risks have felt it most, making placing hard-to-insure risks like these an increasingly specialised task.

So this article explains what EPS actually is, where it tends to hide in commercial buildings, why underwriters treat it as a fire-related property risk rather than a construction detail, and exactly what information to gather before you go to market or renew.

What EPS actually is, in insurance terms

EPS stands for expanded polystyrene, a lightweight, rigid plastic foam used for insulation and temperature control. The part that catches people out is that you rarely see it. In commercial buildings it is usually sealed inside insulated sandwich panels, between facings of sheet metal, plasterboard or concrete, or concealed within walls and ceilings, so from the inside of a cool room all you see is a clean metal wall with the combustible core sitting behind it.

It is used because it works and because it is cheap. EPS is light, easy to install, cost-effective and an efficient insulator at low temperatures, which is precisely why it became the default for cool rooms and temperature-controlled spaces. Some newer panels use a fire-retardant grade, but those still make up a small share of the total building stock, so the age of construction, along with the building materials used, is one of what drives your premiums and how a risk is viewed.

Where EPS turns up in Australian commercial property

The highest-probability locations are anywhere temperature is controlled: cool rooms, freezer rooms, food manufacturing and processing areas, food storage, butcheries, hospitality back-of-house and large cold storage facilities. If your building chills, freezes or processes food, assume EPS is present until you can prove otherwise.

Beyond that it appears in internal wall and ceiling panels in factories and warehouses, lightweight wall sheeting, external cladding and rendered panel systems, modular or relocatable buildings, and retrofitted insulated areas added to older structures. A tenant fitting out half a warehouse as a chilled store in 2009 may well have installed several hundred square metres of it without anyone recording the fact.

That is the usual reason occupiers cannot answer the insurer's question, because the panels pre-date the lease, sit behind linings, or belong to a fit-out nobody documented. Practical first checks include building plans and specifications, panel labels or stamps on the panel edge, installation and fit-out records, maintenance files, previous risk survey or engineering reports, and annual fire safety documentation. Where the paperwork runs out, have a builder, engineer or fire safety consultant inspect exposed panel edges, damaged sections and ceiling voids; a qualified opinion in writing is worth far more to an underwriter than your best guess, particularly when it comes to arranging commercial property insurance for stock that accurately reflects the risks present in your building.

Why expanded polystyrene insurance questions are really fire questions

Underwriters are not objecting to insulation, they are pricing fire load. EPS is a combustible material built into the fabric of the building, so a fire has more fuel available to it and the potential severity of a loss rises accordingly. Exposed to fire or sustained high heat, EPS can ignite quickly, spread flame rapidly and release toxic gases, and because it sits behind panel facings, fire can move through it out of sight.

That concealment is the crux of the problem, because a sealed, undamaged panel behaves very differently to one with an exposed core at a damaged corner, an unsealed joint, or an unsleeved cable penetration. Poor detailing around services, doorways, ceilings, electrical cabling and kitchen flues gives fire a path into the core, which is why insurers ask about panel condition rather than just panel presence. Electrical equipment fixed directly to EPS walls, and flues passing through combustible panels without protection, are specific and recurring concerns.

For the fire brigade, a fire inside a panel core is hard to locate, hard to reach and hard to contain. That is what turns a contained incident into a total-loss event, and it shows up in claims history: the market's caution followed a run of multi-million dollar fires at Australian food industry sites over the past decade.

None of which means the word EPS decides your outcome on its own. Underwriters assess the whole risk, so how much there is, where it sits, what the occupancy does, what the ignition sources are, and what separation, detection, suppression and management controls surround it all feed into the view they take.

How insurers typically respond when EPS is present

Expect detailed questions before you see a price. Insurers commonly want to know whether EPS is present at all, what percentage of wall, ceiling or roof construction it makes up, whether it is fire-retardant grade, where it is located (external cladding, internal panelling, cold-store construction), how close it sits to heat sources such as machinery, kitchens or switchboards, and what fire protection and inspection regimes are in place.

Those answers shape the outcome, which can range from a normal quote with a risk-improvement schedule attached, through higher premiums or excesses and narrower terms, to specific exclusions, restricted capacity or declinature. As a broad market rule, most traditional Australian insurers will consider SME risks where EPS makes up no more than around 20 to 30 percent of floor space, while larger exposures are assessed case by case and acceptance depends heavily on housekeeping and risk management standards. Where local capacity runs out, overseas markets have historically picked up the difficult risks, though appetite there has narrowed too, which is why many businesses with heavier EPS exposure end up seeking out specialist EPS insurance cover (https://www.matrixinsurance.net.au/expanded-polystyrene-eps-insurance/) rather than relying on standard placements.

Occupancy is the other big lever. Food production, cold storage, commercial cooking, welding and other hot work, forklift and two-way radio battery charging, and significant electrical plant all attract closer scrutiny because they put ignition sources near a combustible core. Sprinklers, smoke and heat detection, gaseous suppression in switch rooms, fire-rated separation, hot-work permits, disciplined housekeeping and documented maintenance pull the assessment back the other way.

The honest summary is that having EPS does not make a property uninsurable, but unmanaged EPS, or EPS you cannot describe accurately, makes cover harder and dearer to secure. There is a claims dimension as well, because understating the extent of EPS is a material non-disclosure issue that can reduce or void a claim after a fire, which is the worst possible time to discover the number on your proposal form was a guess.

The four areas to document in an EPS evidence file
The four areas to document in an EPS evidence file

The information to gather before you go to market

Build an EPS file and keep it current, because underwriters respond to evidence and a submission with photographs, reports and dates behind it is assessed on facts rather than assumptions. There are four areas to work through.

Extent and specification. Record panel type and core material, the manufacturer and age where known, whether it is fire-retardant grade, the total area involved, and the percentage of wall, ceiling and roof construction it represents, then attach installation records, panel certification and any specification sheets you can find.

Condition and construction. Note damaged panels and exposed cores, unsealed joints and apertures, service and cable penetrations, doorways, ceiling voids, external cladding areas, and where fire-rated walls and doors provide separation. Photograph the problem areas and log what has been repaired and when.

Fire protection. List sprinkler coverage, smoke and heat detection above ceilings as well as below, gaseous suppression in switch rooms, ammonia detection where refrigeration plant is present, fire doors and fire walls, thermographic imaging of switchboards and fire panels, and your annual fire safety inspection records.

Operating controls. Document hot and cold work permits, contractor induction and supervision, housekeeping standards, storage of pallets, cartons and wrapping well clear of panel walls, the location of forklift and radio charging stations, cleaning schedules for kitchen flues and extraction fans, and how often you inspect panel integrity.

Then do one more thing and decide what you will fix. Replacing old or damaged panels with fire-retardant alternatives, sealing apertures, sleeving cabling in fire-retardant conduit and moving ignition sources away from panel walls all reduce the underlying risk, and documenting that work, including what it cost, shows the market a proactive owner rather than an unknown quantity. That distinction is usually worth more at renewal than any wording you could negotiate.

Subscribe to our newsletter